Octet Number |
Description |
Note |
Status |
10 |
Parameter category |
Code/Flag Table 4.1 |
Operational |
11 |
Parameter number |
Code/Flag Table 4.2 |
Operational |
12-13 |
Input process identifier |
(see Note 1) |
Operational |
14-15 |
Input originating centre |
(see Common Code table C-11 and Note 2) |
Operational |
16 |
Type of post-processing |
(see Note 3) |
Operational |
17 |
Type of generating process |
Code/Flag Table 4.3 |
Operational |
18 |
Background generating process identifier (defined by originating centre) |
|
Operational |
19 |
Forecast generating process identifier (defined by originating centre) |
|
Operational |
20-21 |
Hours after reference time of data cut-off |
(see Note 4) |
Operational |
22 |
Minutes after reference time of data cut-off |
|
Operational |
23 |
Indicator of unit of time range |
Code/Flag Table 4.4 |
Operational |
24-27 |
Forecast time in units defined by octet 23 |
(see Note 5) |
Operational |
28 |
Type of first fixed surface |
Code/Flag Table 4.5 |
Operational |
29 |
Scale factor of first fixed surface |
|
Operational |
30-33 |
Scaled value of first fixed surface |
|
Operational |
34 |
Type of second fixed surface |
Code/Flag Table 4.5 |
Operational |
35 |
Scale factor of second fixed surface |
|
Operational |
36-39 |
Scaled value of second fixed surface |
|
Operational |
40 |
Type of ensemble forecast |
Code/Flag Table 4.6 |
Operational |
41 |
Perturbation number |
|
Operational |
42 |
Number of forecasts in ensemble |
|
Operational |
43-44 |
Year of end of overall time interval |
|
Operational |
45 |
Month of end of overall time interval |
|
Operational |
46 |
Day of end of overall time interval |
|
Operational |
47 |
Hour of end of overall time interval |
|
Operational |
48 |
Minute of end of overall time interval |
|
Operational |
49 |
Second of end of overall time interval |
|
Operational |
50 |
n - number of time range specifications describing the time intervals used to calculate the statistically processed field |
|
Operational |
51-54 |
Total number of data values missing in statistical process |
|
Operational |
|
55-66 Specification of the outermost (or only) time range over which statistical processing is done |
|
Operational |
55 |
Statistical process used to calculate the processed field from the field at each time increment during the time range |
Code/Flag Table 4.10 |
Operational |
56 |
Type of time increment between successive fields used in the statistical processing |
Code/Flag Table 4.11 |
Operational |
57 |
Indicator of unit of time for time range over which statistical processing is done |
Code/Flag Table 4.4 |
Operational |
58-61 |
Length of the time range over which statistical processing is done, in units defined by the previous octet |
|
Operational |
62 |
Indicator of unit of time for the increment between the successive fields used |
Code/Flag Table 4.4 |
Operational |
63-66 |
Time increment between successive fields, in units defined by the previous octet |
(see Notes 6 and 7) |
Operational |
|
67-nn These octets are included only if n > 1, where nn = 54 + 12 x n |
|
Operational |
67-78 |
As octets 55 to 66, next innermost step of processing |
|
Operational |
79-nn |
Additional time range specifications, included in accordance with the value of n. Contents as octets 55 to 66, repeated as necessary |
|
Operational |