Octet Number |
Description |
Note |
Status |
10 |
Parameter category |
Code/Flag Table 4.1 |
Operational |
11 |
Parameter number |
Code/Flag Table 4.2 |
Operational |
12 |
Type of generating process |
Code/Flag Table 4.3 |
Operational |
13 |
Background generating process identifier (defined by originating centre) |
|
Operational |
14 |
Forecast generating process identifier (defined by originating centre) |
|
Operational |
15-16 |
Hours after reference time of data cut-off |
(see Note) |
Operational |
17 |
Minutes after reference time of data cut-off |
|
Operational |
18 |
Indicator of unit of time range |
Code/Flag Table 4.4 |
Operational |
19-22 |
Forecast time in units defined by octet 18 |
|
Operational |
23 |
Type of first fixed surface |
Code/Flag Table 4.5 |
Operational |
24 |
Scale factor of first fixed surface |
|
Operational |
25-28 |
Scaled value of first fixed surface |
|
Operational |
29 |
Type of second fixed surface |
Code/Flag Table 4.5 |
Operational |
30 |
Scale factor of second fixed surface |
|
Operational |
31-34 |
Scaled value of second fixed surface |
|
Operational |
35 |
NC - number of categories |
|
Operational |
|
36- Repeat the following 12 octets for each category (i = 1,NC) |
|
Operational |
(36+12(i-1)) |
Code figure |
|
Operational |
(37+12(i-1)) |
Type of interval for first and second limits |
Code/Flag Table 4.91 |
Operational |
(38+12(i-1)) |
Scale factor of first limit |
|
Operational |
(39+12(i-1))-(42+12(i-1)) |
Scaled value of first limit |
|
Operational |
(43+12(i-1)) |
Scale factor of second limit |
|
Operational |
(44+12(i-1))-(47+12(i-1)) |
Scaled value of second limit |
|
Operational |