Octet Number |
Description |
Note |
Status |
|
49-60 Specification of the outermost (or only) time range over which statistical processing is done |
|
Operational |
|
61-nn These octets are included only if n > 1, where nn = 48 + 12 x n |
|
Operational |
10 |
Parameter category |
Code/Flag Table 4.1 |
Operational |
11 |
Parameter number |
Code/Flag Table 4.2 |
Operational |
12-13 |
Atmospheric chemical constituent type |
Code/Flag Table 4.230 |
Operational |
14 |
Type of generating process |
Code/Flag Table 4.3 |
Operational |
15 |
Background generating process identifier (defined by originating centre) |
|
Operational |
16 |
Analysis or forecast generating process identifier (defined by originating centre) |
|
Operational |
17-18 |
Hours after reference time of data cut-off |
(see Note 1) |
Operational |
19 |
Minutes after reference time of data cut-off |
|
Operational |
20 |
Indicator of unit of time range |
Code/Flag Table 4.4 |
Operational |
21-24 |
Forecast time in units defined by octet 20 |
(see Note 2) |
Operational |
25 |
Type of first fixed surface |
Code/Flag Table 4.5 |
Operational |
26 |
Scale factor of first fixed surface |
|
Operational |
27-30 |
Scaled value of first fixed surface |
|
Operational |
31 |
Type of second fixed surface |
Code/Flag Table 4.5 |
Operational |
32 |
Scale factor of second fixed surface |
|
Operational |
33-36 |
Scaled value of second fixed surface |
|
Operational |
37-38 |
Year |
|
Operational |
39 |
Month |
|
Operational |
40 |
Day |
|
Operational |
41 |
Hour |
|
Operational |
42 |
Minute |
|
Operational |
43 |
Second |
|
Operational |
44 |
n - number of time range specifications describing the time intervals used to calculate the statistically processed field |
|
Operational |
45-48 |
Total number of data values missing in statistical process |
|
Operational |
49 |
Statistical process used to calculate the processed field from the field at each time increment during the time range |
Code/Flag Table 4.10 |
Operational |
50 |
Type of time increment between successive fields used in the statistical processing |
Code/Flag Table 4.11 |
Operational |
51 |
Indicator of unit of time for time range over which statistical processing is done |
Code/Flag Table 4.4 |
Operational |
52-55 |
Length of the time range over which statistical processing is done, in units defined by the previous octet |
|
Operational |
56 |
Indicator of unit of time for the increment between the successive fields used |
Code/Flag Table 4.4 |
Operational |
57-60 |
Time increment between successive fields, in units defined by the previous octet |
(see Notes 3 and 4) |
Operational |
61-72 |
As octets 49 to 60, next innermost step of processing |
|
Operational |
73-nn |
Additional time range specifications, included in accordance with the value of n. Contents as octets 49 to 60, repeated as necessary |
|
Operational |