Code/Flag Figure |
Description |
Status |
1
|
Radiometric calibration failed or is degraded
|
Operational
|
2
|
OBCT view counts averaged value over scans is missing (this is valid for the high-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
3
|
Cold space view counts averaged value over scans is missing (this is valid for the low-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
4
|
OBCT view counts averaged value over scans is degraded due to missing or anomalous counts values (this is valid for the high-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
5
|
Cold space view counts averaged value over scans is degraded due to missing or anomalous counts values (this is valid for the low-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
6
|
OBCT view radiance averaged value over scans is missing (this is valid for the high-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
7
|
Cold space view radiance averaged value over scans is missing (this is valid for the low-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
8
|
OBCT view radiance averaged value over scans is degraded due to missing or anomalous values (this is valid for the high-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
9
|
Cold space view radiance averaged value over scans is degraded due to missing or anomalous values (this is valid for the low-reference calibration load when the back-up calibration is applied for channels MWI-1 to MWI-3)
|
Operational
|
10
|
Non-linearity parameter computed using noise diodes is missing (meaningful only for channels MWI-1 to MWI-3)
|
Operational
|
11
|
Non-linearity parameter computed using noise diodes is degraded (meaningful only for channels MWI-1 to MWI-3)
|
Operational
|
12
|
PRTs or THMs temperatures of current scan are missing or with anomalous readings
|
Operational
|
13
|
Moon intrusion in cold space degraded calibration (less than Nvalid_c valid samples are not affected by Moon for the considered channel and scan)
|
Operational
|
14
|
Back-up calibration with noise diodes performed (meaningful only for MWI-1 to MWI-3)
|
Operational
|
15
|
Degraded receiver temperatures lead to degraded calibration
|
Operational
|
All 16
|
Missing
|
Operational
|