  "_id": "033101",
  "name": "ICI calibration flag",
  "values": [
    {
      "_id": "033101",
      "codeentry": "Radiometric calibration failed or is degraded",
      "codefigure": "1",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "OBCT view counts averaged value over scans is missing",
      "codefigure": "2",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Cold space view counts averaged value over scans is missing",
      "codefigure": "3",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "OBCT view counts averaged value over scans is degraded due to missing or anomalous counts values",
      "codefigure": "4",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Cold space view counts averaged value over scans is degraded due to missing or anomalous counts values",
      "codefigure": "5",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "OBCT view radiance averaged value over scans is missing",
      "codefigure": "6",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Cold space view radiance averaged value over scans is missing",
      "codefigure": "7",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "OBCT view radiance averaged value over scans is degraded due to missing or anomalous values",
      "codefigure": "8",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Cold space view radiance averaged value over scans is degraded due to missing or anomalous values",
      "codefigure": "9",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "PRT or THM temperatures of current scan are missing or with anomalous readings",
      "codefigure": "10",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Moon intrusion in cold space degraded calibration (less than Nvalid_c valid samples are not affected by Moon for the considered channel and scan)",
      "codefigure": "11",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Degraded or missing back-end temperatures lead to degraded calibration",
      "codefigure": "12",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Reserved",
      "codefigure": "13-15",
      "status": "Operational"
    },
    {
      "_id": "033101",
      "codeentry": "Missing",
      "codefigure": "All 16",
      "status": "Operational"
    }
  ]
}